5kg dry powder extinguisher
The most common configuration of the parking garage co-working corridor is the most extensive.
Fire Extinguishers & Fire Safety ProductsCar parks, rear staircases, smoke-stop staircases and industrial building corridors may attract little attention day to day, but they can become critical during a fire. They are escape routes and also routes along which fire and smoke can spread. The provision of fire extinguishers and other fire safety equipment therefore directly affects the safety of the entire building. Prepared by Fire Station, Hong Kong fire extinguisher specialists, this guide explains legal requirements, fire risks, the selection of approved extinguishers, positioning, signs and inspections for property managers, owners' corporations, car park operators and industrial tenants.
Key Points: A 30-Second Overview
Home-based fire alarms mainly affect their own units, but when accidents occur in the parking lot, smoke-proof stairs, and the corridor of the factory building, smoke and fire can spread quickly to several floors, or even into buildings. And these places are usually under-populated, and they are easily undetected at an early stage, until people notice that they have missed the golden time.
Fire extinguishers in public locations are three different from those in private establishments:
The minimum requirements are set out in the Code, but the day-to-day maintenance, placement, marking and inspection are done by the Administration with stakeholders.
The following are the regulations and guidelines that are most relevant to the parking lot, the stairs and the fire extinguishers.
| Regulation / Guidance | Scope of application | Focus on fire extinguishers |
|---|---|---|
| Fire Protection (Equipping and Equipment) Regulations (Chapter 95B) | All premises equipped with fire-fighting devices and equipment | Equipment must remain operational at all times; at least once every 12 months will be checked by the registered contractor; FS251 certificates will be issued and copies sent to the fire department within 14 days of completion |
| Code of Minimum Fire Protection Devices and Equipment ( Fire Protection Service) | Construction of new buildings and alterations, including parking | Garages equipped with electrical vehicle charging facilities, which require an additional dry powder or carbon dioxide extinguisher at each larynx location on the floor of the facility |
| Fire Services Department circular No. 4-2020 and subsequent updates | Parking facilities with charging facilities for electric vehicles | Additional provisions include: fire detection systems for providing dry powder or CO2 fire extinguishers, heat or composite sensor detectors for each larynx location (except for flowers that have been sprayed); emergency switch for firefighters |
| Fire Safety (Industrial Buildings) Regulations (Chapter 636) | Target industrial buildings completed on or before 1 March 1987, or first submitted on or before that date | Entered into force on 19 June 2020; the Fire Department and the Buildings Department could issue fire safety instructions to owners to improve fire safety installations and equipment |
| Fire Safety (Buildings) Regulations (Chapter 572) | Joint-use building built on or before 1 March 1987 | Improved fire-fighting installations in the public part of the old building; Fire Services Department Circular No. 3/2026 receiving the Internet fire detection system with hand-held fire extinguishers as an alternative to setting up the larynx system on the 6th floor or below with the requirements of the hand-controlled fire alarm system |
| Department of Labour, Fire at Work Guidelines | Various duty stations, including workshops, warehouses and offices | Appropriate fire extinguishers are provided to address different fire risks; equipment is properly maintained and placed in easily accessible and unblocked locations; employees need to know how to use fire extinguishers at the same side. |
If you want to learn more about common laws and regulations, such as "I don't care if the building is equipped," Hong Kong Fire Safety Regulations: Common Mythsdown.

There is a large amount of fuel for vehicles, batteries and tyres in the parking lot, together with electrical equipment such as lighting systems, exhaust fans, watch rooms and distribution cabinets. A light-fired species, such as short circuits for vehicle wires, illegal modifications, overheating of electric brakes, and the presence of miscellaneous items on or near a car, have the opportunity to turn into fires. The garage is difficult to smoke and the smoke will accumulate quickly, affecting both escape and rescue.
Common risk position in the garage:
The Fire Department has attached fire safety provisions to the parking lot with electrical vehicle charging facilities.
If you intend to charge the parking lot, you should seek, at the beginning of the project, a certified fire-fighting contractor to evaluate with the accredited person and not wait for completion. In addition, the Fire Services Department has issued fire-safety regulations for battery rooms and charging facilities (communication No. 3/2025), which involve large quantities of battery storage.
Hand-held fire extinguishers are only suitable for handling initial firework s, such as charge cables, plugs or charge-post cases. If lithium batteries have become hot and out of control (large quantities of white smoke, hissing, flames) the fire will be strong and easily rekindled, and ordinary people should not risk being rescued. The correct approach is to stop charging, notify others, immediately evacuate and call 999 if it is safe .
If you want to actually see how the parking lot is configured, you can refer Customer Fire Safety Case Studiescustomer's use of the example of the front-runner parking lot and the trust parking lot.
The smoke-resistant stairway system was designed to allow residents and their employees to escape during fire alarms, in conjunction with the ventilation or pressure design of the building, to reduce smoke intrusion. The smoke-proof doors are kept closed and cannot be held up or locked to death by groceries, otherwise the smoke will enter the stairwell quickly. If the stairwells are packed with private, paper-boxed and miscellaneous items, on the one hand there is an obstacle to flight and on the other hand there is a large amount of fuel.
Many buildings are surrounded by fire hydrants and larynx, sometimes supplemented by hand-held fire extinguishers to facilitate initial fire alarms in the corridors or stairs. People can be handled immediately in a safe location. However, the main function of the smoke-proof stairs is always to escape, fire extinguishers are only auxiliary tools and must be used to ensure that they have a safe exit route.
The common use of the old-style complex, which is regulated by chapter 572, may require improvements to the common sector in accordance with fire safety instructions. Fire Services Department Circular No. 3/2026 admits target buildings on or below the sixth floor, using a networked fire detection system as an alternative to hand-held fire extinguishers, To comply with the requirement to set up a larynx system and a hand-held fire alarm system. In other words, the role of hand-held fire extinguishers in improving fire safety in the old small buildings is becoming increasingly important, and when instructed to do so, the Mission may consult with the registered contractor on viable options.
How to divide emergency lights with exit lights can be seen Emergency Lighting & Exit Signs Explained.
In Hong Kong, factory buildings are used for a wide variety of purposes, some of which are still traditional manufacturing workshops, and some have become mini-warehouses, studios, studios, band houses or start-ups offices. The temperature of a fire and smoke rises very quickly when the common point system is rich, dense and complex and partly modified or split. In 2016, a mini-barracker in a big industrial village raised social concerns about fire safety at the same time as the mini-bar.
Common risks at work:
The Department of Labour ' s Fire Prevention Guidelines for Workplaces list the use of various types of fire extinguishers: carbon dioxide for electric fires and flammable liquids; Water for wood, plastics, textiles and paper; Netifier suitable for electronic instruments or documents; Foams suitable for flammable liquids; Dry powder is the widest applicable. Employers should ensure that employees are aware of the placement of fire extinguishers and of the different types of scope of application.
If your work was completed on or before 1 March 1987, or if you first presented a chart on or before that date, it would be the target industrial building of Chapter 636. The Fire Department and the Buildings Department may issue fire safety instructions to the owner to improve fire safety installations and equipment. The owners of the instructions received, together with the legal corps, should be approached as soon as possible for a registered fire operator to follow up with accredited persons. Chapter 636 does not apply if the building as a whole is already subject to Chapter 502 or 572.
The following table shows fire extinguishers approved by Fire Services Department, which is permanently available.
| Products | Height | Scope of application | Garage / common position at work |
|---|---|---|---|
| 5kg dry powder extinguisher | About 50 cm | Paper, cloth, wood, solvent, fuel fuel, power buttons | Station area, by the throat, work corridor, warehouse |
| 2kg dry powder extinguisher | About 36 cm | Paper, cloth, wood, solvent, fuel fuel, power buttons | Fee booths, management rooms, small units, studios |
| 5kg CO2 extinguisher | About 64 cm | Solvents, fuel fuel, power buttons | Electric, watch, machine, large control cabinets |
| 2kg CO2 extinguisher | About 50 cm | Solvents, fuel fuel, power buttons | Near chargers, servers, charge-back systems |
| 9L Foam agent fire extinguishers | About 62 cm | Paper, cloth, wood, solvent, fuel | Vehicle maintenance space, workshop for storage of fuel solvents |
| 9L Water extinguishers | About 56 cm | Paper, cloth, wood. | Solid paper or fabric warehouse (unsuitable for electrical and oil fires) |
| Fire cans. | About 25 cm x 25 cm | Small oil spills, early fire. | Parking, public spaces |
| Fire extinguisher sticker | — | Marking of fire extinguishers | Pillars, stairwell platforms, corridors |

The most common configuration of the parking garage co-working corridor is the most extensive.
Fire Extinguishers & Fire Safety Products
The electrical room, the machine room and the control cabinet were near, and there were no residues.
Fire Extinguishers & Fire Safety Products
The parking lot handles minor oil spills in common with the initial fires.
Fire Extinguishers & Fire Safety ProductsIn order to understand the advantages and disadvantages of the different types of fire extinguishers, we can see A Complete Guide to Fire Extinguishers in Hong Kongfor How to Choose a Fire Extinguisher in Hong KongKong.
The fire extinguisher should be clearly marked whether it is a parking lot or a stairway.

The Department of Labour’s Workplace Fire Guide states that fire-fighting equipment should be placed in a position where it is easily accessible and unblock ed, and that no one should destroy or interfere with fire-fighting equipment.
| Check items | Normal | How do we deal with the problem? |
|---|---|---|
| Location to Number | Each of them is in a designated position, not removed. | Put it back in place and buy it back if lost. |
| Pressure table | Pointers in green range (CO2 fire extinguishers usually have no pressure table) | Arrangements for contractor inspection, refilling or replacement |
| Insurance plugs and seals. | It's intact. It's not unopened. | Suspected of having been used, arrange an inspection. |
| The squirm with the nozzle. | No rust, dents, cracks or leaks. | Disable and replace |
| Hang up and place it. | Steady. Fire extinguishers didn't fall. | Maintenance or replacement of hangers |
| Front channel. | No groceries, vehicles or cargo shielding. | Immediately clear and notify the tenants concerned |
| Label & Check Record | The model, the method of use and the date of inspection are clear. | Retrieve the tags and check the annual logs. |
| Indicator sticker | It's clear. It's not faded or covered. | New sticker replacement |
In addition to daily inspections, the law clearly requires that fire installations and equipment be inspected by a registered fire operator at least once every 12 months . After the contractor has completed the installation, maintenance, repair or inspection, it must issue to its client, within 14 days , a certificate of FS251 fire protection devices and equipment . And send a copy to the fire department. Hand-held fire extinguishers, blankets and sand drums fall within the scope of work of the class 3 registered contractor .
In view of the large amount of co-working equipment in the garage, it is proposed that the Administration:
Detailed checks show Fire Extinguisher Inspection & Replacementfor Fire Extinguisher Servicing or Replacementers. Old drums can be used as fire extinguisher recovery services for Fire StationFire Extinguisher Recycling Serviceas Fire Extinguisher Recycling & Disposal.
Fire StationIt's in the Bay of Wing.Specialized fire extinguisher shopThe sameFire-fighting equipment supplierIt's in the industrial zone.G/F, Karrie Industrial Centre, Pak Tin Par Street, Tsuen WanWe provide fire extinguishers, installation and maintenance services to customers such as the exhibition mall and the parking garage, the prestigious parking lot and the speed line.
You can watch it first.Customer Fire Safety Case StudiesThe sameFire Safety Equipment Upgrade Case StudiesOnce you have the information available, you can do it.WhatsApp 96309976Call.3464 3987Or go.Contact Fire StationKeep information low.
There are also additional requirements for fire detection systems and emergency switches for firefighters.
The area of parking is usually dominated by dry powder extinguishers, since dry powder applies to most fire alarms, including flammable liquids such as fuel.
The Fire Safety (Industrial Buildings) Ordinance (Chapter 636), which came into force on 19 June 2020, applies to construction on or before 1 March 1987, Or the target industrial building for which the building chart was first submitted on or before that date. The Fire Department and the Buildings Department may issue fire safety instructions to the owner to improve fire safety installations and equipment.
The Department of Labour’s Workplace Fire Guide states that fire-fighting equipment at the workplace should be properly maintained and placed in a position where it is easily accessible and unobstructed, and that no one should destroy or interfere with fire-fighting equipment.
In accordance with the Fire Protection (Equipment and Equipment) Regulations, fire protection installations and equipment at premises are inspected at least once every 12 months by a registered fire protection contractor. The contractor is required to issue the FS251 certificate within 14 days of completion of the work and send a copy to the Fire Services Department. Hand-held fire extinguishers fall within the scope of the Registered Contractor No. 3. The Service should also arrange daily inspections.
Fire extinguishers should be placed on a stair platform or in an eye position against a wall, along with emergency lights and exit signs.
Fire extinguishers are only suitable for initial fireworks, such as charge cables or plug-in smoke. If the lithium batteries of electric vehicles have become hot out of control, smoke is high, or the fire is expanding, they should stop charging, immediately evacuate and call 999 under safe conditions, and should not risk being rescued at close range.
Fire Station at G/F, Karrie Industrial Centre, Pak Tin Par Street, Tsuen Wan In this case, the dry powder approved by the Supply Fire Services Department, together with carbon dioxide extinguishers, sand drums and fire extinguisher stickers, has been packaged for basic delivery and can be arranged for door-to-door installation, annual inspection and maintenance, and FS251 certificates are issued by a level III fire operator. 3464 3987 ,WhatsApp 96309976 。
Fire extinguishers in public or semi-public spaces are not just for "offer work" but for real tools to buy time in the early days of the fire. As of today, pay attention to the fact that every fire extinguisher in the parking lot, in the stairwells and in the halls of the same work, has been kept in place, is not available and has not expired. An additional layer of security has been added to the building building. If you want a professional team to take a look at your current configuration, please Contact Fire Station.
Extend Reading
Fire Station has approved a valid fire extinguisher, has packaged basic deliveries, and a third-level fire operator issues a FS251 certificate.