2kg dry powder extinguisher
About 36 cm, applicable to paper, cloth, wood, solvents, fuel and power switches, preferred in the general office area.
Fire Extinguishers & Fire Safety ProductsOffice fires do not always begin with an obvious mistake. Often, nobody has regularly checked the wiring, fire extinguishers, escape routes or emergency lighting. The Labour Department's workplace fire prevention guidance calls for adequate escape routes, suitable firefighting equipment and staff who know how to respond. Prepared by Fire Station, Hong Kong fire extinguisher specialists, this practical checklist separates the responsibilities of business owners and administrators from those of property managers and building management offices. Daily, monthly, quarterly and annual schedules help you review office fire safety systematically.
Key Points: A 30-Second Overview
The office is safe and secure, but the fire risks are hidden on the surface of the day-to-day operation: plug-in overload, boxes filled with corridors, fire extinguishers expired, exit lights are broken, fire doors are blocked. The Fire Department's work review in 2025 indicates that the main cause of fire in disaster buildings is electrical failure (about 42 per cent) and the same human factor (about 25 per cent). And the office is exactly where electrical appliances and towboards are most dense.
There's a fixed check list to help you:
| Regulation / Guidance | Focus related to the office |
|---|---|
| Fire Protection (Equipping and Equipment) Regulations (Chapter 95B) | Hand-held fire extinguishers, blankets to be approved by the Chief of Fire Services Department, may be supplied or sold; fire-fighting installations and equipment must remain in operational condition at all times and be inspected at least once every 12 months by the registered contractor; certification of FS251 is issued by the contractor within 14 days of completion of the work and copies sent to the Fire Services Department |
| Fire Safety (Commercial Places) Ordinance (Chapter 502) | Regulation of commercial buildings identified by commercial premises (commercial buildings built or first presented on or before 1 March 1987) where the Fire Services Department and the Buildings Department can issue fire safety instructions for improvement |
| Department of Labour, Fire at Work Guidelines | Duty stations need to have adequate escape routes; appropriate fire extinguishers are provided to address different fire risks; equipment needs to be properly maintained and placed in accessible and unblocked locations; and employees need to know the location of fire extinguishers, their use and the actions to be taken when they are used |
| Building Fire Safety Code 2011 | Design requirements such as fire lanes, fire doors, fire-resistant structures; renovations and inter-spacing changes |
If you want to know how many fire extinguishers you want to place in your office, you can see Fire Extinguisher Planning for Shops & Offices; common laws and regulations are misinterpreted to see Hong Kong Fire Safety Regulations: Common Myths.
The following table shows the general division of labour, depending on the terms of the lease, contract and law.
| Item | Company owner/administrative | Property Management/Management Service |
|---|---|---|
| Unit fire extinguishers | • Purchase, placement, annual inspection, preservation of FS251 | — |
| Public part throats, fire extinguishers | Don't block it. We've got damage alert. | Maintenance, annual inspection |
| Intra-unit passage and exit | Keep it open. | — |
| Corridors, smoke-resistant stairs, fireproof doors | Don't pile anything. Don't hold the fire doors. | Inspection, clean-up, maintenance |
| Fire alarms, flower sprinklers. | Don't cover the detector with the flowers. | Maintenance, annual inspection |
| Emergency lighting, exit lights | Unit equipment (if any) | Public sector testing and annual testing |
| Power safe. | Trailboards, appliances, server rooms | Public electrical watch room, machine room |
| Staff training, exercises | • Organization and participation | • Coordinated full-seat exercises |
| Location | Main risks | Recommended fire extinguishers |
|---|---|---|
| Reception, general office areas | Paper, private, computer. | Fire Extinguishers & Fire Safety Products |
| Server room, computer room | Electrical equipment | Fire Extinguishers & Fire Safety Productsno powder spent) |
| Print area, photocopy room | Photocopier overheating, paper | Carbon dioxide or dry powder extinguishers |
| Tea room. | Microwave ovens, hot water stoves, multistores | Dry powder extinguishers; blankets for fire if cooked |
| Documentary warehouse, archives | Lots of paper. | Dry powder extinguishers |
If a fire extinguisher is found to be obsolete, damaged or used, it should be arranged as soon as possible for the registered contractor to inspect or replace the fire extinguisher. The old cartridge can be processed with Fire Station Fire Extinguisher Recycling Service, as Fire Extinguisher Inspection & Replacement.
The Department’s guidelines state that the escape route must be sufficiently illuminated and clearly marked.
If you want to understand the division of labour, you can see Emergency Lighting & Exit Signs Explained; the replacement device can refer Emergency Lighting & Exit Signs.
If the building is built on or before 1 March 1987 or is presented for the first time, it may belong to the designated commercial building of Chapter 502.
The Department of Labour directs that, in addition to requiring fire-fighting equipment, it also emphasizes that employees need to know how fire extinguishers are placed on the side, how they should be used, and what action should be taken in case of a fire.
It is recommended that they be held at least once a year, in conjunction with the overall arrangements of the Building Management Service; a large staff member or a new staff member’s building should be arranged as soon as possible. The exercise will help staff to familiarize themselves with escape routes, stairs and assembly points.
Training content and processes can be used to refer Fire Extinguisher & Staff Fire Safety Training. How to Use a Fire Extinguisher: PASS & Common Mistakesbe found in Small-Fire Response: Extinguish or Evacuate?.
| Frequency | Head | Check items |
|---|---|---|
| Daily | Last time I left a colleague. | Closure of non-required appliances and trailers; no miscellaneous items at the same exit |
| Monthly | Head of the floor fire department. | Fire extinguisher position, pressure table, seals to be inserted, no cover in front; fire lanes open; towboards unbuttoned |
| Quarterly | Chief of Administration/Security | Reconcile annual inspection due dates; co-management information on the status of building fire installations; fire profiles for new staff; organize improvements |
| Annual | Company management + registered contractor | Annual fire extinguisher inspection and FS251; fire alarm exercises; review of number of fire extinguishers at the same location |
| Refurbishment/after relocation | Administrative + Contractor | Re-evaluate fire extinguisher placements, escape routes and instructions |
If you want to do anything, you need to have a record.
These documents are useful for fire patrols, insurance claims or staff enquiries.
Fire Station is a specialized fire extinguisher shop located in Tsuen Wan with a fire-fighting equipment supplier, supplying fire-fighting department-approved fire extinguishers and other fire-fighting equipment, with customers including malls, parking lots, logistics companies and serial brands.

About 36 cm, applicable to paper, cloth, wood, solvents, fuel and power switches, preferred in the general office area.
Fire Extinguishers & Fire Safety Products
It's about 50 cm. It's for electrical and computer applications, with no residues, and the server room is the preferred.
Fire Extinguishers & Fire Safety Products
The location of each fire extinguisher is singled out for the attention of colleagues.
Fire Extinguishers & Fire Safety ProductsOnce you have the information, you can do it.WhatsApp 96309976Call.3464 3987Or go.Contact Fire StationLeave a low profile. You can go if you want to see an example of a business customer.Customer Fire Safety Case Studies。
In accordance with the Fire Protection (Equipment and Equipment) Regulations, fire protection installations and equipment at the premises are kept in operational condition at all times and are inspected at least once every 12 months by a registered fire protection contractor. The contractor is required to issue the FS251 certificate within 14 days of its completion and send a copy to the Fire Services Department. The company should also observe itself on a monthly basis.
Both are responsible. Public parts of the building, such as corridors, stairs, throats, fire alarms and emergency lighting, are generally the responsibility of the owner, the legal corps or the management company; fire extinguishers, access, electricity and staff training within the tenant unit are the responsibility of the employer or occupier, depending on the same law as the lease.
The ILO Fire at Work Guidelines state that there should be sufficient escape routes for duty stations to provide suitable fire extinguishers to cope with different fire risks, that fire extinguishing equipment should be located in locations that are easily accessible and unblocked, and that employees should be made aware of the use of fire extinguishers, as well as of the action taken in case of fire alarms.
General office areas can be used for dry powder extinguishers, with the broadest scope of application; electrical intensive locations such as server rooms, computer rooms, photocopying areas are more suitable for carbon dioxide extinguishers, run out of powder and have less impact on electronic equipment.
No. The fire doors are designed to prevent fire and smoke from spreading, and the use of wedges, garbage cans or mats to hold the doors will render them ineffective. They should remain closed at all times and be automatically closed.
It is recommended that this be done at least once a year and in conjunction with the overall arrangements of the Building Management Service; if there is a large staff movement or a new move to the building, arrangements should be made as soon as possible.
Emergency lighting is also a fire-fighting device, which is checked every 12 months by a registered fire-fighting contractor.
Fire Station at G/F, Karrie Industrial Centre, Pak Tin Par Street, Tsuen Wan The supply of dry powder and carbon dioxide extinguishers, approved by the Fire Services Department, has been packaged and delivered to the Hong Kong New Territories, which can arrange for door-to-door installation, annual inspection and the issuance of FS251 certificates by a level III fire operator. 3464 3987 ,WhatsApp 96309976 。
Translating fire safety checks into a regular practice is not an additional burden for companies, but a basic act of accountability to employees, customers and themselves. This list will be added to the to-do list, starting with the next regular office meeting, with the designation of the responsible person, which will be scheduled on the same monthly and annual dates. Need qualified fire extinguishers or professional advice, welcome Contact Fire Station.
Extend Reading
Fire Station provides the Fire Services Department with certified fire extinguishers, which have packaged basic deliveries, and FS251 certificates are issued by a third-level fire operator.