2kg dry powder extinguisher
About 36 cm, which applies to paper, cloths, wood, solvents, fuel and electrical switches, which are most commonly used in the same offices.
Fire Extinguishers & Fire Safety ProductsOpening a shop or moving an office already involves leases, refurbishment and stock, with fire safety requirements adding another set of decisions. Owners often ask: how many fire extinguishers do we need, and where should they go? Prepared by Fire Station, Hong Kong fire extinguisher specialists, this guide first explains the requirements stated in the relevant Hong Kong regulations. It then uses shops, restaurants, cafés, clinics, beauty salons and offices to explain how to choose, position and maintain approved extinguishers, so you can discuss your premises with the landlord, management office and contractor.
Key Points: A 30-Second Overview
The following are the rules and documents most relevant to the business.
| Legislation / Documentation | Scope of application | Focus on fire extinguishers |
|---|---|---|
| Fire Protection (Equipping and Equipment) Regulations (Chapter 95B) | All fire-fighting installations and equipment throughout the port | Article 3: Hand-held equipment, such as hand-held fire extinguishers and blankets, shall be approved by the Chief of Fire Services Department and may be supplied or sold. Article 8 (1): The equipment shall be kept in operational condition at all times and inspected by the registered contractor at least once every 12 months |
| Fire Safety (Commercial Places) Ordinance (Chapter 502) | For example, for use in commercial premises, such as over 230 square metres, banks, off-site betting stations, jewellery and gold shops, supermarkets, department stores or malls, and for the identification of commercial buildings | At least one hand-held fire extinguisher per 100 m2 floor area (less than 100 m2 and 100 m2); not applicable to premises equipped with a fire-fighting larynx system |
| Fire safety regulations for food licence plates of the Fire Services Department | General, small, factory canteens, bakeries, etc. | Type, specification and quantity of authorized hand-held firefighting equipment, by location, for example, 9 litres of water, 4.5 kg of carbon dioxide extinguishers, 1.44 m2 of blankets for fire control; normal food consumption generally requires the installation of automatic fire suppression systems that meet UL-300 standards at the boiler and frying sites |
| Building Fire Safety Code 2011 | Design and alteration of buildings | Design requirements such as fire escapes, fire-resilient structures, etc.; renovations, intervals, etc. |
| Department of Labour, Fire at Work Guidelines | Various duty stations | To provide suitable fire extinguishers to address different fire risk; to place the equipment in a position where it is easily accessible and unblocked; and to know how to use the fire extinguishers at the side. |
Assuming that a commercial is subject to regulation 502, the floor area is 350 square meters (approximately 3,767 square feet) and there is no fire-fighting larynx system. 350 100 = 3.5, less than 100 m2 is also counted as 100 m2, so a minimum of 4 hand-held fire extinguishers are required. This number is the minimum legal requirement, and the actual placement takes care of each area.
If you want to learn more about common misunderstandings, such as "I don't care if the building is equipped" , Hong Kong Fire Safety Regulations: Common Myths.
The final number is determined by the professionals according to the regulations and the situation on the ground, but you can first make a rough assessment using the following five factors:
The larger the area, the more fire extinguishers are needed and distributed in different locations to ensure that anything can move quickly to the nearest one.
The more numerous the entrances and the more complex the flow of people, the more careful the placements.
It is more difficult to evacuate a large number of shops, excluding the number of fire extinguishers, and more important is the availability of trained and well-informed employees.
The regulations applicable to the same building, which is located in the dining room and in the penthouse, may differ completely from the requirements of the licence plate.
The range of fire extinguishers can Fire Extinguishers & Fire Safety Productsor A Complete Guide to Fire Extinguishers in Hong Kong.
The following table shows the general practice of common businesses, for reference purposes only.
| Type of business | Major fire risk | Recommended fire suppression equipment | Common Places |
|---|---|---|---|
| Small retail stores | Boxes, packaging, light box wires | Fire Extinguishers & Fire Safety Products | Inside the gate, near the cash register. |
| Fashion stores, private stores. | Fabrics, timber, large stocks | Dry powder extinguishers; pure fabric or paper silos with water | Front entrance, back entrance. |
| Dining room, teahouse. | Cooking pans, gas stoves, gas-smoking systems | Water, carbon dioxide fire extinguishers and fire blankets are common, as prescribed by the fire department. | Kitchen entrance, dining area entrance and exit. |
| Cafe, light food store. | Coffee machines, stoves, electrical appliances | Dry powder or carbon dioxide extinguishers, fire blankets | It's near the bar, the kitchen entrance. |
| Clinics, beauty salons | Instruments, fine appliances, alcohol use. | Dry powder extinguishers; CO2 for instrumentation rooms | Outside the reception, the instrument room. |
| Hairhouse. | Wind cylinders, straight hair clips, flammable sprays | 2kg dry powder extinguisher | The entrance, near the product storage. |
| Small office | Computer, towboard, paper | Dry powder or 2kg CO2 extinguisher | Near the entrance. |
| The whole floor of the building. | Lots of appliances, servers, files. | Dry powder fire extinguishers in subdistricts; Fire Extinguishers & Fire Safety Products | Reception, printing area, outside the server room |

There is usually only one entrance, two or three employees, and the shelf is concentrated.
For example, a fashion store, a chain of retail sales, and a small private store.
The number of fire extinguishers is determined by law (in the absence of a larynx system, at least one for every 100 square metres).
In order to harmonize specifications in multiple branches, it is possible to refer Customer Fire Safety Case Studiesthe VANGO convenience store in China.
For example, the Fire Services Department's Standard on Fire Safety for Eating Foods (Quick Foods) provides that the building's original fire-fighting equipment must be placed at a specified percentage of the approved type of portable fire-fighting equipment, such as:
The file shows how many units each have to be put together, so the number of fire extinguishers in the restaurant is to be implemented according to fire department regulations, without self-assessing. The usual diet is in all stoves, boilers and frying positions, with the automatic sprinklers system removed, and an automatic fire control or fire suppression system is to be installed that meets the U L-300 test criteria.
If the usual food or factory canteens are to use a card-carat gas stove between the seats, the relevant card-holders condition is that the premises are to be equipped with an automatic graft system and 2.5 kilograms of dry powder hand-held fire extinguishers are to be placed between the seats, one per 100 square metres, plus one per VIP room or spaced room.
The details of the fire protection in the kitchen can be seen Fire Blankets & Kitchen Fire Safety, the handling of the cooking oil boilers can be seen Small-Fire Response: Extinguish or Evacuate?ers.
Café usually has appliances such as coffee machines, stoves, and sandwich machines, which have less fuel than medium kitchens, but overheated appliances are as dangerous as local open fires.
Most of the clinics and beauty salons are located in commercial buildings with small space, but electrical density is high, such as instruments, heating lights and disinfection equipment; the waiting areas are covered with handiwork, and the smoke will be filled with a single unit quickly.
Many of the A1 buildings have their own well-developed fire protection systems, which can be supplemented by hand-held fire extinguishers in tenant units.
For example, accounting buildings, design firms, small agents.
A fire extinguisher is clearly insufficient for dozens or more of employees.
A Office Fire Safety Checklist.
Every fire extinguisher above or near it should have a "fire extinguisher" sticker, which can be used with arrows where it is large or has a corner. Fire Station Fire Extinguishers & Fire Safety Productsto facilitate uniformity of style.
The Department of Labour directs employees to know how to use fire extinguishers.
Training arrangements may refer Fire Extinguisher & Staff Fire Safety Training. Details of How to Use a Fire Extinguisher: PASS & Common Mistakesare used.
Many tenants assume that they are solely responsible for the fire-fighting equipment by the owner or the administration. In practice, fire-fighting devices in the common part of the building are generally the responsibility of the owner, the legal community, or the management company, but most of the equipment in the unit that is required by licence or by statute is the responsibility of the occupier or owner, depending on the same legal requirements as the lease.
| Item | General party responsible | What tenants do. |
|---|---|---|
| Public part of the building, larynx, fire alarm, emergency lighting | Owners, members of the judiciary or management companies | Don't block it. We'll call the D.A. |
| Fire extinguishers set up by license plate or by statute in the unit | Occupant or owner (depending on the lease) | Purchase of approved products, organization of annual inspections, preservation of FS251 |
| Renovation of fire-fighting installations | By a registered fire-fighting contractor | Prior to commencement of work, notify the owner and the Administration and obtain the relevant certificate upon completion |
| Staff training in fire suppression and evacuation | Employers | Organization of training and exercises |
Once you're clear, you'll have fire patrols, license applications or insurance inquiries later.
Fire protection devices and equipment set up by law must remain operational at all times and be inspected at least once every 12 months by a registered fire-fighting operator. After completing the inspection, maintenance or repair, the contractor must issue an F S251 fire-fighting device and equipment certificate within 14 days. And send a copy to the fire department. Hand-held fire extinguishers and blankets are covered by the class 3 registered contractor.
Note that, following the amendment of the Fire Protection (Equipment and Equipment) Regulations, 2024, only portable fire-fighting equipment set up by a household on a voluntary basis at home is exempted from inspection.
Details can be found Fire Extinguisher Inspection & Replacement. Fire Extinguisher Servicing or Replacementas Fire Extinguisher Recycling Serviceservice.
| Phase | Something to do. |
|---|---|
| Before the contract. | Identification of building usage and applicable regulations; clarification of existing fire-fighting equipment, annual inspection records and segregation of duties |
| Applying for license plates | Waiting for licensed premises, observing fire safety regulations issued by the fire department, preparing fire extinguishers and blankets, as required |
| During renovation | Don't block the original throat and exit; Fire Extinguisher Rental in Hong Kong |
| Before opening, | Purchase of fire extinguishers approved by the Fire Services Department, installation of hangers and stickers; issuance of FS251 by registered contractors; Emergency Lighting & Exit Signs |
| After the opening, | Training of new staff; monthly self-inspection; annual inspection every 12 months; maintenance of certificates and records |
| Relocation / Completion | Identification of who the fire extinguisher belongs to; end-of-life or no longer used Fire Extinguisher Recycling Service |
Fire Station is a specialized fire extinguisher shop, a specialized fire-fighting stores and a fire-fighting equipment supplier located in Wing Bay, which specialize s in the supply of fire extinguishers approved by the Fire Services Department. Clients include malls, chained retail brands, convenience stores, logistics companies and parking lots.

About 36 cm, which applies to paper, cloths, wood, solvents, fuel and electrical switches, which are most commonly used in the same offices.
Fire Extinguishers & Fire Safety Products
It's about 50 cm. It's for electrical and computer applications, and it's empty.
Fire Extinguishers & Fire Safety Products
About 24 cm x 20 cm, hanging in the kitchen, handling little cooking oil fires.
Fire Extinguishers & Fire Safety ProductsOther models include 1kg and 5kg dry powder, 5kg carbon dioxide, 9L water and 9L foam fire extinguishers.
Once you have the information, you can do it.WhatsApp 96309976Call.3464 3987Or go.Contact Fire StationKeep information low.
Depending on the purpose of the place, the area, the building regulations and the requirements of the same licence plate. For example, in the case of the commercial premises regulated by regulation 502, there is a minimum of one hand-held fire extinguisher per 100 square metres of floor space (less than 100 square metres, as well as 100 square metres). However, this is not applicable where a fire-fighting larynx system has been installed. If you wait for a licensed place, you will be assigned to the fire safety regulations issued by the Fire Services Department. The actual quantity should be assessed on site by the registered fire operator.
The Fire Services Department will issue fire safety regulations for individual meals, specifying the type, specification and quantity of authorized hand-held fire-fighting equipment to be placed, such as 9 litres of water extinguishers, 4.5 kilograms of carbon dioxide extinguishers and 1.44 square metres of blanket fire-fighting. Ordinary cooking stoves, in combination with fried areas, are typically equipped with automatic fire suppression systems that meet UL-300 standards.
General office areas can be used for dry powder extinguishers, with the broadest scope of application; electrically dense locations, such as server rooms, computer rooms and photocopying areas, are more suitable for carbon dioxide extinguishers, run out of powder and have less impact on electronic equipment.
Need. Fire-fighting installations and equipment set up in accordance with the law shall remain in operational condition at all times and shall be inspected at least once every 12 months by a registered fire-fighting operator. The contractor is required to issue the FS251 certificate within 14 days of its completion and send a copy to the Fire Services Department. Only portable fire-fighting equipment voluntarily installed by households in their homes has been exempted since 2024, and commercial establishments are excluded from the exemption.
According to Article 3 of Chapter 95B, all handheld equipment (e.g. hand-held fire extinguishers, blankets) must be approved by the Chief of Fire Services Department. It can first be supplied or sold in Hong Kong. You can check the list of authorized handheld equipment published by the fire department, or use the "handheld" "cleaning" function of the mobile fire department application. Scan tag identification.
As a general rule, fire-fighting installations in the common-use part of the building are the responsibility of the owner, the LegCo or the management company, and equipment in the unit that is required by licence plate or by statute is the responsibility of the owner or owner, depending on the same legal requirements of the lease agreement.
Fire blankets should be mounted near the kitchen entrance and not above the top of the stove.
Fire Station at G/F, Karrie Industrial Centre, Pak Tin Par Street, Tsuen Wan Dry powder, carbon dioxide, water agents, foam extinguishers and fire blankets, approved by the Fire Services Department, have been packaged for basic deliveries, which can be arranged for door-to-door installation, annual inspection and maintenance, and FS251 certificates issued by level III fire operators. 3464 3987 ,WhatsApp 96309976 。
The fire extinguisher configuration of the compositing and offices is not aimed at "stacking into walls" but at the number and correct location of the code. Add trained users . Early planning, if there's a fire in the first place, you'll have to protect the employees, the customers, and the business. To use your position for specific suggestions, welcome Contact Fire Station.
Extend Reading
Fire Station provides the Fire Services Department with certified fire extinguishers, has packaged basic deliveries, and is issued with a FS251 certificate by a third-degree fire operator.